Seismic Vulnerability Assessment of Structures |
|
Advertisements
|
Experimental testing may be adequate to determine the seismic performance of a single building. However, it is not feasible to determine the seismic performance of a building stock, located in a city, by experimentally testing their representative models. Therefore, seismic performance of a building stock located in a city is evaluated by using a technique known as seismic risk assessment. Seismic risk assessment can be defined as a combination of seismic hazard and vulnerability. Seismic hazard depends upon geology of the area under consideration and is, therefore, site specific. Seismic vulnerability depends upon:
|
There are various approaches regarding assessment of seismic vulnerability of a building stock. Detailed discussion on this topic is given by Lang. According to Lang, various methods for seismic vulnerability can be classified as given in Table 2.1. These methods are briefly discussed in the following sub-sections. Observed vulnerabilityThis method of assessment is based on the statistics of the buildings' damage from the past earthquakes. The method is specifically suitable for poor quality non-engineered construction whose resistance is difficult to calculate by analytical or numerical methods. First such type of a study was made by Whitman. He gathered the data of approximately 1600 buildings damaged due to the San Fernando earthquake of 9th February, 1971. Based on the gathered data, he carried out a statistical analysis and developed damage probability matrices (DPM). These DPM indicated the probability of occurrence of various distress levels at various intensities of earthquake. Other examples of seismic vulnerability assessment, based on observed vulnerability method also exist. The method has the disadvantage of requiring a substantial amount of data inventory. Additionally, the analysis of the data, for the area under consideration, cannot be extended to other towns and cities. Similarly, the method does not possess the ability to calculate reduction in vulnerability of buildings as a result of retrofitting or strengthening of buildings. Vulnerability functions based on expert opinionsThe first such kind of seismic vulnerability assessment was carried out by Applied Technology Council (ATC) under the sponsorship of the Federal Emergency Management Agency (FEMA) of USA. The results of the study were summarized in a report (ATC 13). The ATC -13 report developed the DPM for 78 earthquake engineering facilities, out of which 40 belonged to buildings. These DPM were developed by asking 58 experts to estimate expected percentage of damage that a specific structural type would undergo under the action of various intensities of earthquake. Each expert was asked to fill a comprehensive questionnaire by utilizing their best knowledge. Since then a number of modified and improved versions of such type of a methodology have been proposed [KNKH 97, PCM 00, FKLG 01]. However, the drawback of the methodology lies in the subjective opinion. Each expert, depending upon his knowledge and engineering judgment has his own opinion. In addition, the results obtained for the target area cannot be extended to other towns and cities. Another drawback of the observed vulnerability and expert opinion methods of vulnerability assessment is that these methods cannot be applied to areas with no past earthquake experience. Analytical approach based on simple modelsVulnerability assessment methods of observed vulnerability or expert opinions are applicable to areas with some past earthquake experience. For other areas, analytical methods for determining the seismic vulnerability are needed. Analytical methods using simple building models are based on a small number of input parameters. Consequently, these have the advantage of analyzing a large number of buildings in a relatively short period of time. The efficiency of a method increases if the input parameters required for analyzing the buildings can properly capture the overall seismic behavior of the buildings. One such method is developed by D'Ayala et al for earthquake loss estimation of historical towns of Europe. The method has been used for earthquake loss estimation of a case study in Alfama district, Portugal and villages hit by the Umbria-Marche earthquakes in 1997.Two types of collapse mechanisms, namely,in-planeand,out-of-planeare considered. The potential collapse mechanism and the corresponding capacity are determined by the geometry and boundary conditions, usually based on visual observations. The in-plane and out-of-plane collapse mechanisms are further divided into various subclasses as shown in Figure 1. Each collapse mechanism is related to a damage grade recommended by European Macroseismic Scale 98. Another such approach, applicable to both masonry and R.C. structures, was developed by Calvi and was applied to Catania City. The method only considers in-plane failure modes and ignores the possibility of out-of-plane failure of wall. The model is based on only few number of parameters such period during which the building was constructed, construction material and number of stories in the building. The analysis of the building, by this method, is carried out in order to determine the displacement capacity and the displacement corresponding to various defined limit states. Whereas, the displacement demand is determined by using displacement spectrum. The structural model of each type of building (i.e masonry or R.C) is defined by two parameters, namely, equivalent period of vibration and displacement demand reduction factor (determined by using energy dissipation characteristic of building structure) The methods of analytical model based on simple models have the advantage of analyzing a large number of building stock in a relatively short time. However, the assumptions made for simplification purpose affect the accuracy of results. Score assignmentThis method is aimed at identifying a seismically hazardous building situated in a target area. Structural deficiencies, based on correlation between observed damage and structural characteristics, are identified. Based on different structural deficiencies, scores are then assigned by experts. 该方法作为sc的第一阶段reening seismically hazardous buildings in an area. Buildings with very low scores are then investigated in detail. First such type of methodology was proposed by the Applied Technology Council. The methodology was aimed at developing a procedure for evaluating the seismic performance of existing building in order to identify hazardous buildings that can impose risk to human lives. Since then, a number of improved versions have been proposed. The advantage of this method over vulnerability assessment methods based on observations and expert opinion is that vulnerability assessment of the buildings in a target area can be updated after the retrofitting or strengthening of buildings. Detailed analysis procedures for Seismic Vulnerability of BuildingsThe buildings identified as hazardous from the method of score assignment need further detailed investigation for a final decision. The method used for this purpose can be divided into two classes, namely, static and dynamic procedures. Each method can be further sub-divided in two methods, namely, linear and non-linear methods. This makes a total of four methods as follows:
然而,这些方法是费时的,而不是suitable for an earthquake scenario project in which a lot of buildings need to be investigated. |